SARS-CoV-2 N protein antibody

References #1
Category:
Catalogue No.: 
FNab10600
Alias: 
2019 nCOV N protein antibody
Gene Name: 
SARS-CoV-2
UniProt ID: 
P0DTC9
Size Price
1mg Inquiry
Dispatch Time: About 3 working days
Contact Us
Product Name
SARS-CoV-2 N protein antibody
Catalogue No.
FNab10600
Gene Name
SARS-CoV-2
UniProt ID
P0DTC9
Alias
2019 nCOV N protein antibody
Isotype
IgG
Clone ID
6H9
Form
liquid
Purification
protein A purified
Immunogen
2019 nCOV N protein
Recommended dilution
ELISA: Use at an assay dependent concentration(Suggestions: Use a concentration of 0.1 - 1μg/ml)
Purity
≥95% as determined by SDS-PAGE
Storage
PBS buffer, pH 7.5,-20℃ for 12 months(Avoid repeated freeze / thaw cycles.)


Figures for this product are not available in this catalogue.

Storage
PBS buffer, pH 7.5,-20℃ for 12 months(Avoid repeated freeze / thaw cycles.)
Dispatch Time
About 3 working days
Ordering & Delivery
How do I place an order?
Use the Inquiry button on this page or write to tekintolga89@gmail.com. Include the catalogue number and the quantity you need.
What is the dispatch time?
In-stock items are dispatched within 1-3 business days. Items that need to be produced take longer; we confirm the date when you order.
Do you ship outside Türkiye?
Shipping is arranged case by case. Contact us with the destination and we will quote carriage and lead time.
Storage & Handling
How should an unopened kit be stored?
At 2-8 °C unless the datasheet says otherwise. Do not freeze a kit that is not marked for freezing.
How long is an opened kit stable?
It depends on the component. The Kit Components table on this page lists the storage condition for each item after opening.
What should I do if the shipment arrives warm?
Photograph the package and contact us the same day. Do not use the kit until we have confirmed it is still within specification.
Assay Questions
Which sample types can I use?
The Sample Type row in the specifications above lists the validated matrices for this product. Other matrices need validation on your side.
My background is too high. What should I check?
The usual causes are insufficient washing, contaminated buffers, or too much detection antibody. Our Protocol pages cover the full troubleshooting sequence.
Can I run fewer wells than the kit provides?
Yes. Dismountable microplates let you use part of a plate and reseal the rest with the desiccant supplied.
Technical Support
Something did not work. What do you need from me?
Send the catalogue number, the lot, your protocol deviations and the raw OD values. That is usually enough to identify the cause.
Do you provide a certificate of analysis?
Yes, per lot. Ask for it with the catalogue number and lot number.

Aradığınızı bulamadınız mı? Tüm SSS sayfasına bakın veya bize yazın.

Product Comparison

Compare